ADEMCO VISTA SERIES VISTA-20P / VISTA-20PSIA VISTA-15P / VISTA-15PSIA Security Systems Programming Guide K5305-1PRV5 10/04 Rev. Which is better ic7610 or kenwood ts 890s. OPEN CIRCUIT (or OC): The Keypad is not communicating with the main control panel. Long Rng Trbl (or bF): If installed, there is an issue with long-range communication; TELCO FAULT (Or CHECK 94): The telephone line has a problem. That's it, you're done! This tip is applicable for the following alarm panels: Honeywell Vista 10; Honeywell. Complete english basics 4 answers pdf. Cw bmx serial numbers.

Hello all.
I'm having issues connecting my ad2usb ver 2 to my panel. The system without the ad2usb is functioning just fine but when I plug this in, I get an ECP ERROR on my 6280 and open ckt on my 6160rf.
The 6160rf is using address 16.
The 6280 is using address 1.
I also have two expanders.
The decoder is connected to a Mac running 10.8.5
i've tried address 17, 18, 19, and 20 (all open with 1 1 in the panel).
The below is a dump from the keypad app log (disconnected the green and yellow wires):
Starting AlarmDecoderApp build #2.0.10.23844
4/16/2014 11:16:22 PM Loding modules. To remove modules use the modules tab under the about menu
4/16/2014 11:16:22 PM Example V1.0 initialized
4/16/2014 11:16:22 PM keypad V1.0 initialized ()
4/16/2014 11:16:22 PM MyStuff V1.0b initialized
4/16/2014 11:16:32 PM Waiting for communication to AlarmDecoder to open
4/16/2014 11:16:32 PM Communicaiton to AlarmDecoder established
4/16/2014 11:16:32 PM Trying to make sure we are not in config mode sending rn A Bunch!
4/16/2014 11:16:36 PM 4/16/2014 11:16:36 PM Sending 'rn' to check if in config mode.
4/16/2014 11:16:36 PM The AlarmDecoder not in config mode. Continuing to initialize.
4/16/2014 11:16:36 PM Sending 'V' command to the AlarmDecoder
4/16/2014 11:16:36 PM !VER:ffffffff,V2.2a.6,TX;RX;SM;VZ;RF;ZX;RE;AU;3X;CG;DD;MF;LR;KE;MK;CB
4/16/2014 11:16:36 PM Found Version String
4/16/2014 11:16:37 PM Sending 'C' command to the AlarmDecoder
4/16/2014 11:16:37 PM !>
4/16/2014 11:16:37 PM !CONFIG>ADDRESS=20&CONFIGBITS=ff00&LRR=N&EXP=NNNNN&REL=NNNN&MASK=ffffffff&DEDUPLICATE=N
4/16/2014 11:16:37 PM Found and saving Config String
4/16/2014 11:16:39 PM Sending 'rn' command to the AlarmDecoder
4/16/2014 11:16:49 PM !>Keypad Address (20) :
4/16/2014 11:16:49 PM >!>Config Bits (ff00) :
4/16/2014 11:16:49 PM >!WARNING. Do not enable a module if the physical module exists on the system.
4/16/2014 11:16:49 PM !Zone Expanders Y/N Max allowed: 02
4/16/2014 11:16:49 PM !>expander module #01 ZN 09-16 (N) :
4/16/2014 11:16:49 PM >!>expander module #02 ZN 17-24 (N) :
4/16/2014 11:16:49 PM >!>expander module #03 ZN 25-32 (N) :
4/16/2014 11:16:49 PM >!>expander module #04 ZN 33-40 (N) :
4/16/2014 11:16:49 PM >!>expander module #05 ZN 41-48 (N) :

Honeywell Vista 20p Programming Manual


4/16/2014 11:16:49 PM >!Relay Modules Y/N Max allowed: 04
4/16/2014 11:16:49 PM !>relay module #01 (N) :
4/16/2014 11:16:49 PM >!>relay module #02 (N) :
4/16/2014 11:16:49 PM >!>relay module #03 (N) :

Honeywell Vista 20p Kit

4/16/2014 11:16:49 PM >!>relay module #04 (N) :
4/16/2014 11:16:49 PM >!>Emulate Long Range Radio Y/N: (N) :
4/16/2014 11:16:49 PM >!>Address Filter Mask (ffffffff) :
4/16/2014 11:16:49 PM >!>Deduplicate (N) :
4/16/2014 11:16:49 PM >!Reading configuration.
4/16/2014 11:16:49 PM !UART init.
Honeywell Vista 20p Open Ckt
4/16/2014 11:16:56 PM Restart application for settings to take effect
Thanks for the help!